ThermoBreeze Net Zero

thermobreeze.png

ThermoBreeze Net Zero


The heat pump radiator

The heat pump radiator

Technical data


Specification text

The ThermoBreeze is an advanced heat pump radiator that delivers a powerful, even airflow thanks to its silent tangential fan. This intelligent unit is specifically designed for ultra-low temperature heating and active cooling, making it the perfect complement to any heat pump system. Compact, energy-efficient, and quick to respond, for your comfort in every season.

Product
Decorative ultra-low temperature heat pump radiator with integrated controls and a tangential fan for high output. 2-pipe version. For wall mounting.
Finishing
Decorative casing with integrated, recessed thermostat
Pre-installed
Power supply, thermostat, stainless steel filter
Fan
Tangential fan with vibration damping and 0–10 V control. Start-stop safety during filter mounting and removal
Also supplied
Motorized actuator, low-resistance thermostatic valve, adjustable and isolatable lockshield valve, condensate tray, opening clip, locking screws, screws, plugs, and installation and user manual
Control
Digital thermostat with temperature setting and Modbus. Heating, cooling, and fan modes. Fan speed is automatically controlled or manually adjustable in 5 levels.
Cooling
In combination with a compatible heat pump. Standard-equipped for cooling below (Deep Cooling) or above (Light Cooling) the dew point. No dew point protection is included
Heat exchanger
With corrugated aluminium fins. Integrated air vent on flow and return.
Sound pressure
The sound levels of the ThermoBreeze radiators can be found in the technical documentation.
Connections
2 x ½” internal thread, right-hand connection. Centre connection optional.
Electrical connection
Power supply via 230 VAC mains, to be connected through screws in the built-in 24 VDC power supply. Inside the casing, an opening is provided for cable entry if the power cable comes directly out of the wall into the casing. Provide a minimum cable length of 300 mm from the wall outlet. If the power supply is located outside the radiator, the cable must enter the casing through the lower left side.
Packaging
Each heat pump radiator is packaged in high-quality cardboard. A label describes the radiator characteristics: type – height – length.
Warranty
10 years for the radiator and 2 years for the electrical components, as long as the installation instructions have been followed and Henrad’s warranty conditions have been met.
Paint process
The casing is degreased, phosphated and coated in Henrad NT110 Papyrus white as standard
Colours
Henrad NT110 Papyrus white textured finish + 35 different Henrad colours and about 200 RAL-colours are possible
Max. operating pressure
10 bar
Min./max. operating temp.
5 – 65 °C
Conformity
in accordance with EN16430 and EN12102 (EN3741)
Technical data
Voltage 220-240V ~50Hz, IPX0, Class I
Max. electrical power
19 – 30 – 35 - 42 W
Standby power
0.75 W
Height
465 mm
Lengths
800 – 1.000 – 1.200 – 1.400 mm
Depth
120 mm

Sound pressure

Once the unit reaches the set temperature, the continuously adjusting fan automatically reduces its speed, resulting in lower noise levels. The average sound pressure level in automatic mode of the ThermoBreeze with a length of 800 mm is 26 dB(A) at a distance of 1 metre.

 

How loud is a given decibel level?
db(A)PerceptionExamples
20Virtually inaudiblemorning silence in a forest
26Just audibleThermoBreeze heat pump radiator
30Very quietwhispering
35Quieta gentle rain shower with closed windows
42Moderatelibrary

Mounting and connection

Mounting without centre connection

zonder-middenaansluiting

X = Position of drilling holes, dimensions in mm.

 

Mounting with centre connection (provided the optional accessory is ordered)

met-ma

X = Position of drilling holes, dimensions in mm.
*  = Central connection possible, provided that the optional accessory with the above article number is ordered.

 

Connections

tb_positionering



Mounting and electrical connection

24 VDC screw-type power supply on the left-hand side, with a 230 VAC connection, cable entry via an opening underneath, with a minimum cable length of 300 mm from the wall outlet. For a power connection outside the radiator, the cable must be routed at the lower left side of the casing.
 

elektrische_aansluiting

Composition

FAC-EXPLODED-FULLY-SV-NAMEN-HR-EN

Dew point calculator

Dew Point Calculation